6–2 Hardware Operation
Publication 2755-6.9
Function Command Action
<A> Software Reset (does not save for power-on)
<Ad> Software Reset/Restore Default
<An> Software Reset/Read NOVRAM
Program Management
<D>
Enter Configuration Mode
Program Management
<Z>
Software Reset/Save Parameters for Power-on
<Zd> Restore/Save Default Configuration for Power-on
<Zp> Save Scanner Type, SPS, and Gain for Power-on
<H> Enable Laser Scanning (Laser On)
<I> Disable Laser Scanning (Laser Off)
<KE> Motor On
Device Control
<KF>
Motor Off
<L1> Relay-1 Pulse
<L2> Relay-2 Pulse
<P> Autodiscriminate All Codes
<Q> Enable Code 39 Only
➀
Code Types
<R>
Enable Codabar Only
➀
<S> Enable I 2 of 5 Only
➀
<N> No Read Counter
<O> No Read Counter Reset
<T> Trigger Counter
<U> Trigger Counter Reset
Counter
<V>
Match Code/Good Read Counter
<W> Match Code/Good Read Counter Reset
<X> Mismatch Counter
<Y> Mismatch Counter Reset
<C> Enter Decode Rate Test
Test
<Ce>
Enter Extended Decode Rate Test
Test
<J>
Exit Decode Rate Test; Exit Extended Decode Rate Test
<#> Display Software Part Number
<!> Display Checksum of EPROM
<?> Show Scanner Status
Status
<?1>
Show Software Status (Send Status Byte, Part Number, and ROM
Checksum. Display NOVRAM Checksum at Power Up, then Display
Current NOVRAM Checksum)
<E> Enable Match Code Option
➀
<F> Disable Match Code Option
➀
<G> Store Next Label Scanned as Master Label
Master Label
<)XXXX)>
Download Master Label Information
<)> Request Master Label Information
<))> Delete Master Label Information
➀
The command can also be set in the configuration menu or with a serial configuration command.