12–17Creating Bar Graphs, Indicators, Numeric Displays
Publication 2711-6.0
Editing State Text
The Text field contains the text that will appear for each state. The
default text is the state number (ST 0). Double-click in the cell to
edit the text.
Other text fields control how the text is formatted for each state.
Entering State Values
If Value was selected in the Read area of the Properties tab, the Value
field appears for each state. This field defines the numeric value at
the read tag address that triggers the state to display.
The range of the value you enter must be within the range of the
Data Format selected on the Properties tab. The default value for
each state is the state number (0 to 1,999).
Data Format Range
Binary
0000 0000 0000 0000 to
1111 1111 1111 1111
Unsigned Integer 0 to 65535
Signed Integer -32768 to +32767
4-BCD 0 to 9999
Hexadecimal
0 to FFFF
Octal
0 to 177777
Formats provided for data entry. The terminal does not display/transfer these formats.