
P034 [Minimum Freq]
Values
Default 0.0 Hz
Min/Max: 0.0/300.0 Hz
Display: 0.1 Hz
P035 [Maximum Freq]
Values
Default 60 Hz
Min/Max: 0/300.0 Hz
Display: 1 Hz
A069 [Internal Freq]
Values
Default 60.0 Hz
Min/Max: 0.0/300.0 Hz
Display: 0.1 Hz
A070 [Preset Freq 0]
A071 [Preset Freq 1]
A072 [Preset Freq 2]
A073 [Preset Freq 3]
Values
A070 Default
A071 Default
A072 Default
A073 Default
0.0 Hz
5.0 Hz
10.0 Hz
20.0 Hz
Min/Max: 0.0/300.0 Hz
Display: 0.1 Hz
P042 [DC Brk Pressure] – New Parameter
This is the new parameter, which affects the DC braking performance.
Values
Default 1200
Min/Max: 80/2000
Display: 1
A109 [Ground Fault Avoid] – New Parameter
This is a new parameter, which can be used to avoid the ground fault F13.
Values
Default 0
Min/Max: 0/2
Display: 1
PowerFlex 4 Custom Firmware
Komentáře k této Příručce