Rockwell-automation 20C PowerFlex 700H Drives Programming Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 20C PowerFlex 700H Drives Programming. Rockwell Automation 20C PowerFlex 700H Drives Programming User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 116
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků

Shrnutí obsahu

Strany 1 - Programming Manual

PowerFlex 700H Adjustable Frequency AC DriveFirmware Revisions 1.xxx ... 6.001Programming Manual

Strany 2 - Important User Information

10 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012PrefaceNotes:

Strany 3 - Information

100 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesIs Sleep-WakeWorking?Have these conditions been met?Is Req

Strany 4

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 101Application Notes Appendix BStart At Power UpA powerup delay time of up to 30 seconds

Strany 5 - Table of Contents

102 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesDC BrakeThis method uses DC injection of the motor to Stop

Strany 6 - Appendix C

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 103Appendix CHistory of ChangesChanges to This ManualThis appendix briefly summarizes cha

Strany 7 - What Is Not in this Manual

104 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix C History of ChangesThe information below summarizes the changes to the Power

Strany 8 - General Precautions

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 105History of Changes Appendix CThe information below summarizes the changes to the Progr

Strany 9

106 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix C History of ChangesNotes:

Strany 10

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 107IndexNumerics20C-DG1 Remove 5220C-DG1 Status 52AAccel Mask 46Accel Owner 47Accel Time

Strany 11 - Drive Start-Up

108 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012IndexDC Bus Voltage 20Decel Mask 46Decel Owner 47Decel Time x 30deceleration inhibitst

Strany 12 - Start-Up the Drive

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 109IndexFeedback Select 24FileCommunication 45Dynamic Control 30Inputs & Outputs 49Mo

Strany 13 - Running an Assisted Start Up

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 11Chapter 1Drive Start-UpThis chapter describes how you start up the PowerFlex 700H drive

Strany 14 - Chapter 1 Drive Start-Up

110 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012IndexLoad Limits Group 30load loss faultsubcodes 73Local Mask 46Local Owner 47Logic Ma

Strany 15 - Programming and Parameters

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 111IndexParameters20C-DG1 Remove 5220C-DG1 Status 52Accel Mask 46Accel Owner 47Accel Time

Strany 16

112 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012IndexMOP Mask 46MOP Owner 47MOP Rate 35MOP Reference 20Motor Cntl Sel 22Motor NP FLA 2

Strany 17 - Organized

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 113IndexPI Preload 29PI Prop Gain 28PI Ref Meter 29PI Reference Hi 29PI Reference Lo 29PI

Strany 18 - Dynamic Control

114 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012IndexStart At PowerUp 32start errordigital input 77HIM 77input wiring 77Start Inhibits

Strany 20 - Monitor File

Publication 20C-PM001F-EN-P - March 2012 PN-145180 Supersedes Publication 20C-PM001E-EN-P - April 2010 Copyright © 2012 Rockwell Automation, Inc. All

Strany 21 - Motor Control File

12 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 1 Drive Start-UpApply Power to the Drive❏ 4. Apply AC power and control voltage

Strany 22

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 13Drive Start-Up Chapter 1Running S.M.A.R.T. StartDuring a Start Up, the majority of appl

Strany 23

14 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 1 Drive Start-UpNotes:

Strany 24 - Speed Command File

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 15Chapter 2Programming and ParametersThis chapter provides a complete list and descriptio

Strany 25

16 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersThis table is an example of how each parameter type

Strany 26

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 17Programming and Parameters Chapter 2How Parameters are OrganizedThe LCD HIM displays pa

Strany 27

18 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersAdvanced Parameter View Parameter 196 [Param Access

Strany 28

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 19Programming and Parameters Chapter 2UtilityDirection Config Direction Mode 190HIM Ref C

Strany 29

Important User InformationSolid-state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strany 30 - Dynamic Control File

20 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersMonitor FileFileGroupNo.Parameter Name & Descri

Strany 31

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 21Programming and Parameters Chapter 2Motor Control FileMONITORMetering023 [Speed Referen

Strany 32

22 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersMOTOR CONTROLMotor Data046 [Mtr NP Pwr Units]Select

Strany 33 - (1)(2)(3)

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 23Programming and Parameters Chapter 2MOTOR CONTROLTorq Attributes057 [Flux Up Mode]Flux

Strany 34

24 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersSpeed Command FileFileGroupNo.Parameter Name &

Strany 35 - Utility File

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 25Programming and Parameters Chapter 2SPEED COMMANDSpd Mode/Limits088 [Speed/Torque Mod]S

Strany 36

26 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersSPEED COMMANDSpeed References096 [TB Man Ref Sel]Se

Strany 37

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 27Programming and Parameters Chapter 2SPEED COMMANDSpeed Trim117 [Trim In Select]Specifie

Strany 38

28 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersSPEED COMMANDProcess PI124 [PI Configuration]Sets c

Strany 39

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 29Programming and Parameters Chapter 2SPEED COMMANDProcess PI133 [PI Preload]Sets the val

Strany 40

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 3Summary of ChangesThis manual contains new and updated information. Changes throughout t

Strany 41

30 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersDynamic Control FileFileGroupNo.Parameter Name &

Strany 42

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 31Programming and Parameters Chapter 2DYNAMIC CONTROLStop/Brake Modes155156[Stop/Brk Mode

Strany 43

32 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersDYNAMIC CONTROLStop/Brake Modes164 [Bus Reg Kp]Prop

Strany 44

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 33Programming and Parameters Chapter 2DYNAMIC CONTROLRestart Modes178 [Sleep Wake Mode]En

Strany 45 - Communication File

34 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersDYNAMIC CONTROPower Loss184 [Power Loss Mode]Sets t

Strany 46

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 35Programming and Parameters Chapter 2Utility FileFileGroupNo.Parameter Name & Descri

Strany 47

36 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersUTILITYDrive Memory197 [Reset To Defalts]Resets par

Strany 48

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 37Programming and Parameters Chapter 2UTILITYDrive Memory204 [Dyn UsrSet Cnfg]Enables/Dis

Strany 49 - Inputs/Outputs File

38 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersUTILITYDiagnostics209 [Drive Status 1]Present opera

Strany 50

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 39Programming and Parameters Chapter 2UTILITYDiagnostics212 [Drive Alarm 2]Alarm conditio

Strany 51

4 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Summary of ChangesNotes:

Strany 52

40 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersUTILITYDiagnostics215 [Last Stop Source]Displays th

Strany 53

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 41Programming and Parameters Chapter 2UTILITYDiagnostics227 [Status 1 @ Fault]Captures an

Strany 54

42 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersUTILITYDiagnostics234236[Testpoint 1 Sel][Testpoint

Strany 55

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 43Programming and Parameters Chapter 2UTILITYFaults243245247249251253255257[Fault 1 Code]

Strany 56 - Parameter List by Name

44 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersUTILITYAlarms259 [Alarm Config 1]Enables/disables a

Strany 57

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 45Programming and Parameters Chapter 2Communication FileFileGroupNo.Parameter Name &

Strany 58 - Parameter List by Number

46 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersCOMMUNICATIONComm Control274 [DPI Port Sel]Selects

Strany 59

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 47Programming and Parameters Chapter 2COMMUNICATIONMasks/Owners288 [Stop Owner]Adapters t

Strany 60

48 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersCOMMUNICATIONSDatalinks304305[Data In C1] - Link C

Strany 61 - Troubleshooting

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 49Programming and Parameters Chapter 2Inputs/Outputs FileCOMMUNICATIONSSecurity597 [Write

Strany 62 - Drive Status

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 5Table of ContentsPrefaceWho Should Use this Manual . . . . . . . . . . . . . . . . . . .

Strany 63 - Manually Clear Faults

50 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersINPUTS/OUTPUTSAnalog Inputs321 [Anlg In Sqr Root]En

Strany 64 - Fault and Alarm Descriptions

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 51Programming and Parameters Chapter 2INPUTS/OUTPUTSAnalog Outputs341 [Anlg Out Absolut]S

Strany 65

52 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersINPUTS/OUTPUTSDigital Inputs358 [20C-DG1 Remove]Cle

Strany 66

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 53Programming and Parameters Chapter 2INPUTS/OUTPUTSDigital Inputs361362363364365366[Digi

Strany 67

54 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersINPUTS/OUTPUTSDigital Outputs379 [Dig Out Setpt]Set

Strany 68

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 55Programming and Parameters Chapter 2INPUTS/OUTPUTSDigital OutputsSelected Option Defini

Strany 69

56 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersParameter List by NameParameter Name Number Group P

Strany 70

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 57Programming and Parameters Chapter 2Motor NP FLA 042 Motor Data 2-21Motor NP Hertz 043

Strany 71 - Fault Subcodes

58 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersParameter List by NumberNumber Parameter Name Group

Strany 72

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 59Programming and Parameters Chapter 2217 Dig Out Status Diagnostics 2-40218 Drive Temp D

Strany 73

6 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Table of ContentsAppendix BApplication NotesExternal Brake Resistor . . . . . . . . . .

Strany 74

60 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 2 Programming and ParametersNotes:

Strany 75 - Subcodes

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 61Chapter 3TroubleshootingThis chapter provides information to guide you in troubleshooti

Strany 76

62 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingDrive StatusThe condition or state of your drive is constantly

Strany 77 - Common Drive Symptoms

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 63Troubleshooting Chapter 3Faults and AlarmsA fault is a condition that stops the drive.

Strany 78 - Motor Operation is Unstable

64 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingFault and Alarm DescriptionsTable 1 - Fault/Alarm Types, Descr

Strany 79 - Technical Support Options

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 65Troubleshooting Chapter 310 System Fault 2 One of the following has occurred:• A hardwa

Strany 80

66 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 Troubleshooting23 MaxFreqCnflct 2 The sum of parameters 82 [Maximum Speed] an

Strany 81 - HIM Overview

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 67Troubleshooting Chapter 334 CAN Bus Flt 2 A sent message was not acknowledged.See Table

Strany 82 - ALT Functions

68 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 Troubleshooting70 Power Unit 2 One or more of the output transistors were ope

Strany 83 - Figure 2 - HIM Menu Structure

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 69Troubleshooting Chapter 3106 MCB-PB Config 2 The drive rating information stored on the

Strany 84

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 7PrefaceThe purpose of this manual is to provide you with the basic information needed to

Strany 85 - View and Edit Parameters

70 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingTable 2 - Fault/Alarm Cross Reference135 DigIn CnflctC 2 More

Strany 86 - Remove and Install the HIM

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 71Troubleshooting Chapter 3Fault SubcodesFault Subcodes can be viewed in parameters 543,

Strany 87

72 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingTable 8 - IGBT Over Temperature Fault (F9) Subcode Table 9 - S

Strany 88 - Motor Control Technology

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 73Troubleshooting Chapter 3Table 10 - Over Current Fault (F12) Subcodes Table 11 - Ground

Strany 89 - Trip Time (Sec)

74 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingTable 14 - Output Phase Missing Fault (F21) Subcode Table 15 -

Strany 90

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 75Troubleshooting Chapter 3Table 20 - Heatsink Under Temperature Fault (F37) Subcodes Tab

Strany 91 - Frequency

76 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingTable 22 - NVS Read Checksum Fault (F47) Subcode Table 23 - Mo

Strany 92

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 77Troubleshooting Chapter 3Clear AlarmsAlarms are automatically cleared when the conditio

Strany 93 - PowerFlex 700H drives)

78 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingDrive does not Respond to Changes in Speed Command Motor and/o

Strany 94 - PI Enable

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 79Troubleshooting Chapter 3Stopping the Drive Results in a Decel Inhibit FaultTechnical S

Strany 95 - Normalized Feedback

8 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012PrefaceAdditional ResourcesThese documents contain additional information concerning rel

Strany 96 - Reverse Speed Limit

80 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Chapter 3 TroubleshootingWhat You Need When You Call Tech SupportWhen you contact Techn

Strany 97 - Skip Frequency

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 81Appendix AHIM OverviewExternal and Internal ConnectionsThe PowerFlex 700H drive provide

Strany 98

82 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix A HIM OverviewLCD Display ElementsALT FunctionsTo use an ALT function, press t

Strany 99 - Sleep Wake Mode

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 83HIM Overview Appendix AMenu StructureFigure 2 - HIM Menu StructureUserDisplayDiagnostic

Strany 100 - Appendix B Application Notes

84 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix A HIM OverviewDiagnostics Menu When a fault trips the drive, use this menu to

Strany 101 - Stop Modes

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 85HIM Overview Appendix AThe PowerFlex 700H drive is initially set to Basic Parameter Vie

Strany 102 - (A)(C)(B)

86 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix A HIM OverviewRemove and Install the HIMThe HIM can be removed or installed wh

Strany 103 - History of Changes

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 87Appendix BApplication NotesExternal Brake ResistorFigure 3 - External Brake Resistor Ci

Strany 104

88 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesMotor Control TechnologyWithin the PowerFlex family there a

Strany 105

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 89Application Notes Appendix BMotor OverloadFor single motor applications the drive can b

Strany 106 - Appendix C History of Changes

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 9PrefaceATTENTION: The sheet metal cover and mounting screws on the ASIC Board located on

Strany 107 - Numerics

90 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application Notes[Motor OL Hertz]. For all settings of [Motor OL Hertz] othe

Strany 108

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 91Application Notes Appendix BOverspeedOverspeed Limit is a user programmable value that

Strany 109

92 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application Notes• [DC Bus Voltage] – displays the instantaneous value.• [DC

Strany 110

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 93Application Notes Appendix BProcess PI The internal PI function of the PowerFlex 700H p

Strany 111

94 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesPI EnableThe output of the PI loop can be turned on (enable

Strany 112

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 95Application Notes Appendix BIf no digital input is configured to “PI Enable,” then only

Strany 113

96 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesReverse Speed LimitFigure 6 - [Rev Speed Limit], parameter

Strany 114

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 97Application Notes Appendix BSkip FrequencyFigure 8 - Skip FrequencySome machinery may h

Strany 115

98 Rockwell Automation Publication 20C-PM001F-EN-P - March 2012Appendix B Application NotesSkip Frequency ExamplesThe skip frequency will have hystere

Strany 116 - Documentation Feedback

Rockwell Automation Publication 20C-PM001F-EN-P - March 2012 99Application Notes Appendix BSleep Wake Mode This function stops (sleep) and starts (wak

Komentáře k této Příručce