14 DeviceNet Serial Interface Module
Publication 1799-IN012B-EN-P - July 2008
Receive
message
time-out
9 Get/Set Number of ms to
wait for the next
character in the
string before
defining the
current message
complete and
marking it to
produce on the
DeviceNet
network.
0 = Not active
1…65,635 =
milliseconds to wait f
Not active 0 USINT
Receive
string data
type
10 Get/Set Defines the
format of the
data string sent
to the master.
0 = Array
1 = Short string
2 = String
Short
string
1USINT
Receive Pad
mode
11 Get/Set Indicates
whether to pad
the invalid data
region after the
delimiter with
the pad
character, or to
use variable
length ASCII
responses.
0 = Pad mode
disabled
1 = Pad mode enabled
Enabled 1 USINT
Receive pad
character
12 Get/Set The value to use
to pad the
invalid data
portion of the
poll response.
Any valid standard
ASCII character
Null 0 USINT
Receive
Swap mode
13 Get/Set If enabled, the
position of the
bytes in the
serial messages
is swapped
every 2, 3, or 4
bytes.
0 = Disabled
1 = 16-bit Swap
Enabled
2 = 24-bit Swap
Enabled
3 = 32-bit Swap
Enabled
Disabled 0 USINT
Parameter # Access Description Parameter Choices Default
Setting
Default
Value
Data
Type
Komentáře k této Příručce