48 Manage Controller Communications
The controller has the following limits on the number of connections
that you can cache:
For more information...
The Logix5000 Controllers General Instructions Reference Manual,
1756-RM003 describes how to use the MSG instruction.
The Logix5000 Controllers Common Procedures Manual, 1756-PM001
provides information on how to:
execute a MSG instruction
get and set the number of unconnected buffers
convert INT data to DINT data
manage multiple MSG instructions
send one MSG to multiple devices
If you have this software
and firmware revision:
Then you can cache:
11.x or earlier block transfer messages for up to 16 connections
other types of messages up to 16 connections
12.x or later up to 32 total connections