FLEX Integra and FLEX I/O are
trademarks of Rockwell Automation Publication 1793-5.3 - September 1999
Installation Instructions
FLEX Integra
2 Input/2 Protected Output Module
(Cat. No. 1793-IB2XOB2P and -IB2XOB2PS)
Module Installation
This module mounts on a DIN rail. It connects to an adapter or another
FLEX I/O or Integra module. Note: If using this module with FLEX I/O
modules, do not mount between FLEX I/O modules. Mount Integra
modules to the right of the FLEX I/O modules. To mount this module:
1. Remove the cover plug (if used) in the male connector of the unit to
which you are connecting this module.
2. Position the module on the 35 x 7.5mm DIN rail A (A-B pt. no.
199-DR1).
3. Rotate the module onto the DIN rail with the top of the rail hooked
under the lip on the rear of the module.
41355
30720-M
A
A
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - FLEX Integra

FLEX Integra and FLEX I/O are trademarks of Rockwell Automation Publication 1793-5.3 - September 1999Installation InstructionsFLEX Integra 2 Input/2

Strany 2

10 FLEX Integra 2 Input/2 Protected Output Module Publication 1793-5.3 - September 1999Dimensions in(mm)2.72H x 3.15D x 2.17W(69H x 80D x 55W)Fusing O

Strany 3 - Low Voltage Directive

FLEX Integra 2 Input/2 Protected Output Module 11 Publication 1793-5.3 - September 1999

Strany 4 - 8 9 10 11 12 13 14 15

Publication 1793-5.3 - September 1999 PN 955132-32ASupersedes Publication 1793-5.3 - September 1998 © (1999) Rockwell International Corporation.Printe

Strany 5 - Indicators

2 FLEX Integra 2 Input/2 Protected Output Module Publication 1793-5.3 - September 19994. Press down to lock the module on the DIN rail.If the module d

Strany 6 - FT = Filter time

FLEX Integra 2 Input/2 Protected Output Module 3 Publication 1793-5.3 - September 1999European Union Directive ComplianceIf this

Strany 7

4 FLEX Integra 2 Input/2 Protected Output Module Publication 1793-5.3 - September 1999WiringThis module is available with 2 styles of terminations; 17

Strany 8

FLEX Integra 2 Input/2 Protected Output Module 5 Publication 1793-5.3 - September 1999WiringExample of 2-wire and 3-wire Sensors

Strany 9

6 FLEX Integra 2 Input/2 Protected Output Module Publication 1793-5.3 - September 1999Memory MappingSetting the Input Delay TimeYou can select the inp

Strany 10

FLEX Integra 2 Input/2 Protected Output Module 7 Publication 1793-5.3 - September 1999CUL Hazardous Location ApprovalApprobation

Strany 11

8 FLEX Integra 2 Input/2 Protected Output Module Publication 1793-5.3 - September 1999• Substitution of components may impair suitability for Class

Strany 12

FLEX Integra 2 Input/2 Protected Output Module 9 Publication 1793-5.3 - September 1999Specifications - 2 Input/2 Protected Outp