Publication 1792D-IN017B-EN-P - September 2000
Installation Instructions
ArmorBlock MaXum 4 Input Module
Series B
(Cat. No. 1792D-4BV0D)
This ArmorBlock MaXum I/O module (Cat. No. 1792D-4BV0D) is a
stand-alone 24V dc I/O product which communicates via a
DeviceNet network. The sealed housing of this module requires no
enclosure.
This model has 4 inputs. Inputs are 24V dc automatically configured
for PNP (sourcing) or NPN (sinking) devices. Diagnostic features
included are short circuit and open wire detection reported to the
point level. Local logic control has been added to the Series B version
of this product.
41455
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Series B

Publication 1792D-IN017B-EN-P - September 2000Installation InstructionsArmorBlock MaXum 4 Input Module Series B(Cat. No. 1792D-4BV0D)This ArmorBlock M

Strany 2 - Package Contents

10 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000The following table describes logic status indicators

Strany 3 - Set the Node Address

ArmorBlock MaXum 4 Input Module Series B 11Publication 1792D-IN017B-EN-P - September 2000Specifications4 Input Module - Cat. No. 1792D-4BV0DIn

Strany 4 - Install the Module

12 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000Hazardous Location Approval The following information

Strany 5

ArmorBlock MaXum 4 Input Module Series B 13Publication 1792D-IN017B-EN-P - September 2000Les informations suivantes ne concernent que les prod

Strany 6

14 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000This product has been tested at an Open DeviceNet Ven

Strany 7 - DeviceNet Cable

ArmorBlock MaXum 4 Input Module Series B 15Publication 1792D-IN017B-EN-P - September 2000Notes:

Strany 8

Publication 1792D-IN017B-EN-P - September 2000 PN 957395-42Supersedes Publication 1792D-5.17 - October 1998 © 2000 Rockwell International Corporation.

Strany 9

2 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000Package ContentsYour package contains:• 1 ArmorBlock M

Strany 10

ArmorBlock MaXum 4 Input Module Series B 3Publication 1792D-IN017B-EN-P - September 2000Install Your ArmorBlock MaXum I/O ModuleTo install the

Strany 11 - Specifications

4 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000See the illustration of the node address below.Install

Strany 12 - Hazardous Location Approval

ArmorBlock MaXum 4 Input Module Series B 5Publication 1792D-IN017B-EN-P - September 2000To install the module:1. Position the module over the

Strany 13 - AVERTISSEMENT

6 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000Connect the Input Cord Sets to the MaXum ModuleThis mo

Strany 14

ArmorBlock MaXum 4 Input Module Series B 7Publication 1792D-IN017B-EN-P - September 2000Input connectors for this module are shown below.Devic

Strany 15

8 ArmorBlock MaXum 4 Input Module Series B Publication 1792D-IN017B-EN-P - September 2000Polled - a master initiates communication by sending i

Strany 16

ArmorBlock MaXum 4 Input Module Series B 9Publication 1792D-IN017B-EN-P - September 2000Troubleshoot with the IndicatorsThis module has the fo

Komentáře k této Příručce

Žádné komentáře