Publication 1792D-IN004B-EN-P - August 2000
Installation Instructions
ArmorBlock MaXum 12 Input/
4 Output Module Series B
(Cat. No. 1792D-12BVT4D)
This ArmorBlock MaXum I/O module (Cat. No. 1792D-12BVT4D) is
a stand-alone 24V dc I/O product which communicates via a
DeviceNet network. The sealed housing of this module requires no
enclosure.
This model has 12 inputs and 4 outputs accessed through Y splitter
cables. Inputs are 24V dc automatically configured for PNP (sourcing)
or NPN (sinking) devices. Four self-protected 24V dc outputs can
provide up to 2.0 amp each. Diagnostic features are short circuit,
open wire and no load detection reported to the connector level for
inputs, to point level for outputs. Local logic control has been added
to the Series B version of this product.
I-2
I-9
I-3
I-8
I-0
I-11
I-1
I-10
O-0
O-3
O-1
O-2
I-4
I-7
I-5
I-6
Net/Mod Status
Logic Status
Auxilary Power
42338
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - 4 Output Module Series B

Publication 1792D-IN004B-EN-P - August 2000Installation InstructionsArmorBlock MaXum 12 Input/4 Output Module Series B(Cat. No. 1792D-12BVT4D)This Arm

Strany 2 - Check Package Contents

10 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Refer to the following table for point indica

Strany 3 - Set the Node Address

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 11Publication 1792D-IN004B-EN-P - August 2000The following table describes logic status in

Strany 4

12 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Specifications12 Input / 4 Output Module - Ca

Strany 5

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 13Publication 1792D-IN004B-EN-P - August 200012 Input / 4 Output Module - Cat. No. 1792D-1

Strany 6

14 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Hazardous Location Approval The following inf

Strany 7 - Cyclic 1 Byte 4 Bytes

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 15Publication 1792D-IN004B-EN-P - August 2000Les informations suivantes ne concernent que

Strany 8

Publication 1792D-IN004B-EN-P - August 2000 PN 957400-03Supersedes Publication 1792D-IN004A-US-P - May 2000 © 2000 Rockwell International Corporation.

Strany 9

2 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Check Package ContentsYour package contains:•

Strany 10 - Auxiliary Power

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 3Publication 1792D-IN004B-EN-P - August 2000Install Your ArmorBlock MaXum I/O ModuleTo ins

Strany 11

4 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Refer to the illustration of the node address

Strany 12 - Specifications

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 5Publication 1792D-IN004B-EN-P - August 2000To install the module:1. Position the module o

Strany 13

6 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Use the micro caps to cover and seal unused po

Strany 14 - Hazardous Location Approval

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 7Publication 1792D-IN004B-EN-P - August 2000I/O connectors for this module are shown below

Strany 15 - AVERTISSEMENT

8 ArmorBlock MaXum 12 Input/ 4 Output Module Series B Publication 1792D-IN004B-EN-P - August 2000Cyclic - allows configuration of the block as

Strany 16

ArmorBlock MaXum 12 Input/ 4 Output Module Series B 9Publication 1792D-IN004B-EN-P - August 2000The DeviceNet Network uses advanced network te

Komentáře k této Příručce

Žádné komentáře