Rockwell-automation 1769-HSC Compact High Speed Counter Module Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 1769-HSC Compact High Speed Counter Module. Rockwell Automation 1769-HSC Compact High Speed Counter Module User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 32
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
Installation Instructions
Compact I/O High-speed Counter
Module
Catalog Number
1769-HSC
About the Module
The 1769-HSC module has six differential DC inputs that can be used as two to four high-speed
counters. The module has 4 sourcing DC outputs and 12 additional ‘virtual’ outputs. The
counters provide accumulated pulse counts to the input array of the module and can cause
onboard outputs to react to input conditions at high speed.
The module is compatible with CompactLogix controllers, MicroLogix 1500 controllers , and
the 1769-ADN DeviceNet adapter.
Topic Page
Important User Information 2
Environment and Enclosure 3
North American Hazardous Location Approval 4
Module Features 5
Hardware Description 6
Module Installation 7
System Planning 8
System Assembly 8
System Mounting 10
Replace the Module within a System 12
Field Wiring Connections 13
Output Operation 20
Module Powerup 22
Temperature Derating 23
Specifications 26
Additional Resources 30
Zobrazit stránku 0
1 2 3 4 5 6 ... 31 32

Shrnutí obsahu

Strany 1 - Installation Instructions

Installation InstructionsCompact I/O High-speed Counter ModuleCatalog Number 1769-HSCAbout the ModuleThe 1769-HSC module has six differential DC input

Strany 2 - Important User Information

10 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010System MountingMinimum SpacingMaintain spacing from enclosure w

Strany 3 - Environment and Enclosure

Compact I/O High-speed Counter Module 11Publication 1769-IN030B-EN-P - October 2010Figure 2 - Compact I/O Modules with MicroLogix 1500 Base Unit a

Strany 4 - Risque d’Explosion –

12 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010DIN Rail MountingThe module can be mounted on the following DIN

Strany 5 - Module Features

Compact I/O High-speed Counter Module 13Publication 1769-IN030B-EN-P - October 2010If you feel excessive resistance, make sure that you disconnect

Strany 6 - Hardware Description

14 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Grounding Guidelines•This product is intended to be mounted to

Strany 7 - Module Installation

Compact I/O High-speed Counter Module 15Publication 1769-IN030B-EN-P - October 2010Figure 5 - Single-Ended Encoder Wiring(1) Refer to your encoder

Strany 8 - System Assembly

16 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Figure 6 - Discrete Device Wiring(1) External resistors are req

Strany 9

Compact I/O High-speed Counter Module 17Publication 1769-IN030B-EN-P - October 2010Output WiringBasic wiring(1) of output devices(2) to the module

Strany 10 - System Mounting

18 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Wire the Finger-safe Terminal BlockWhen wiring the terminal blo

Strany 11

Compact I/O High-speed Counter Module 19Publication 1769-IN030B-EN-P - October 2010Wire the ModulesAfter the module is properly installed, wire th

Strany 12 - DIN Rail Mounting

2 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Important User InformationSolid-state equipment has operational

Strany 13 - Field Wiring Connections

20 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Output OperationThe four output terminals must be powered by a

Strany 14 - Wire Diagrams

Compact I/O High-speed Counter Module 21Publication 1769-IN030B-EN-P - October 2010Transistor Output Transient PulsesThe maximum duration of the t

Strany 15 - VDC Vmin–

22 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Module PowerupAt module powerup, a series of internal diagnosti

Strany 16 - VDC Vmin–()

Compact I/O High-speed Counter Module 23Publication 1769-IN030B-EN-P - October 2010Temperature DeratingThe following graphs indicate how much curr

Strany 17 - MODULE TYPE ______

24 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Maximum Output Current per Point - 5V DC OperationMaximum Outpu

Strany 18

Compact I/O High-speed Counter Module 25Publication 1769-IN030B-EN-P - October 2010Maximum Output Current per Point - 24V DC OperationMaximum Outp

Strany 19 - Wire the Modules

26 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Specifications Technical Specifications - 1769-HSCAttribute 176

Strany 20 - Output Operation

Compact I/O High-speed Counter Module 27Publication 1769-IN030B-EN-P - October 2010On-state voltage, min 2.6V DCOn-state current, min 6.8 mAOff-st

Strany 21 - On-State Load Current (mA)

28 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Environmental Specifications - 1769-HSCAttribute 1769-HSCTemper

Strany 22 - Module Powerup

Compact I/O High-speed Counter Module 29Publication 1769-IN030B-EN-P - October 2010EFT/B immunityIEC 61000-4-4±2 kV at 5 kHz on power ports±2 kV a

Strany 23 - Temperature Derating

Compact I/O High-speed Counter Module 3Publication 1769-IN030B-EN-P - October 2010Environment and EnclosurePrevent Electrostatic DischargeATTENTIO

Strany 24 - (104) (122) (140)

30 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Additional ResourcesThese documents contain additional informat

Strany 25

Compact I/O High-speed Counter Module 31Publication 1769-IN030B-EN-P - October 2010Notes:

Strany 26 - Specifications

Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400Publication 1769-IN030B-EN-P - Oct

Strany 27

4 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010North American Hazardous Location ApprovalThe following informat

Strany 28

Compact I/O High-speed Counter Module 5Publication 1769-IN030B-EN-P - October 2010Module FeaturesThe 1769-HSC module is a 1 MHz counter/encoder in

Strany 29 - Certifications - 1769-HSC

6 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010Hardware DescriptionItem Description1Bus lever2a Upper-panel mou

Strany 30 - Additional Resources

Compact I/O High-speed Counter Module 7Publication 1769-IN030B-EN-P - October 2010Module InstallationThe 1769-HSC module is suitable for use in an

Strany 31

8 Compact I/O High-speed Counter ModulePublication 1769-IN030B-EN-P - October 2010System PlanningThere are several factors to consider when planni

Strany 32 - Rockwell Automation Support

Compact I/O High-speed Counter Module 9Publication 1769-IN030B-EN-P - October 2010Refer to the illustration when assembling the Compact I/O system

Komentáře k této Příručce

Žádné komentáře