Rockwell-automation 1761-NET-AIC Advanced Interface Converter (AIC+) U Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 1761-NET-AIC Advanced Interface Converter (AIC+) U. Rockwell Automation 1761-NET-AIC Advanced Interface Converter (AIC+) User Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 46
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
AIC+ Advanced
Interface Converter
Catalog Number 1761-NET-AIC
User Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 45 46

Shrnutí obsahu

Strany 1 - Interface Converter

AIC+ Advanced Interface Converter Catalog Number 1761-NET-AICUser Manual

Strany 2 - Important User Information

Publication 1761-UM004B-EN-P - June 20066 Product OverviewThe communication-rate selector switch is used to match the communication rate filter

Strany 3 - Summary of Changes

Publication 1761-UM004B-EN-P - June 2006Product Overview 7Node Address Identification There is no node address associated with the network port

Strany 4 - 4 Summary of Changes

Publication 1761-UM004B-EN-P - June 20068 Product Overview

Strany 5 - Table of Contents

9 Publication 1761-UM004B-EN-P - June 2006Chapter 2Installation and WiringCompliance to European Union DirectivesIf this product has the CE mark it is

Strany 6 - Appendix A

Publication 1761-UM004B-EN-P - June 200610 Installation and WiringSafety ConsiderationsThis equipment is suitable for use in Class I, Division

Strany 7 - Purpose of This Manual

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 11Mount the AIC+ Advanced Interface ConverterThe AIC+ interface converter can b

Strany 8 - Conventions Used in This

Publication 1761-UM004B-EN-P - June 200612 Installation and WiringMount to a Panel Follow these instructions to mount your AIC+ interface conve

Strany 9 - Product Overview

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 13Wire the AIC+ Advanced Interface ConverterThis section provides power supply

Strany 10 - Operation Modes

Publication 1761-UM004B-EN-P - June 200614 Installation and WiringWire to the Network PortsUse these instructions for wiring Belden cable.Attac

Strany 11 - Node Address Identification

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 15The table below shows connections for Belden #3106A. The table below shows co

Strany 12 - 8 Product Overview

Important User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

Strany 13 - Installation and Wiring

Publication 1761-UM004B-EN-P - June 200616 Installation and WiringCable ChoicesThis section provides information that will help you determine t

Strany 14 - Safety Considerations

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 171761-CBL-AS03 and 1761-CBL-AS09 Cable1761-CBL-AM00 and 1761-CBL-HM02 Cable 17

Strany 15 - Mount the AIC+ Advanced

Publication 1761-UM004B-EN-P - June 200618 Installation and Wiring1761-CBL-AP00 and 1761-CBL-PM02 Cable 1761-CBL-AP00 and 1761-CBL-PM02 CableCa

Strany 16 - Mount to a Panel

Publication 1761-UM004B-EN-P - June 2006Installation and Wiring 19User-supplied CableRecommended User-supplied ComponentsThese components can b

Strany 17 - Wire the AIC+ Advanced

Publication 1761-UM004B-EN-P - June 200620 Installation and Wiring PortsPin # DB-9 RS-232 RS-232 (8-pin mini-DIN) Communication Port(1) (1761-

Strany 18 - IMPORTANT

21 Publication 1761-UM004B-EN-P - June 2006Chapter 3Network Connections Network DiagramsThis chapter provides various network connections. The item nu

Strany 19 - 1219 m (4000 ft) Maximum

Publication 1761-UM004B-EN-P - June 200622 Network ConnectionsComponents Replaced by the AIC+ Interface Converter The AIC+ interface converter

Strany 20 - Cable Choices

Publication 1761-UM004B-EN-P - June 2006Network Connections 23DH-485 Network with SLC 5/03 and SLC 5/04 Processors and a PC DH-485 Network with

Strany 21 - 1761-CBL-HM02

Publication 1761-UM004B-EN-P - June 200624 Network ConnectionsDH-485 Network with a MicroLogix 1000 Controller DH-485 Network with a MicroLogix

Strany 22 - 1761-CBL-AP00

Publication 1761-UM004B-EN-P - June 2006Network Connections 25Networked Operator-interface Device and MicroLogix Controller Networked Operator-

Strany 23 - User-supplied Components

3 Publication 1761-UM004B-EN-P - June 2006Summary of ChangesThe information below summarizes the changes to this manual since the last printing.To hel

Strany 24

Publication 1761-UM004B-EN-P - June 200626 Network ConnectionsNetworks Using Ganged Converters Networks Using Ganged Converters1761-CBL-AS09 or

Strany 25 - Network Connections

Publication 1761-UM004B-EN-P - June 2006Network Connections 27Network Extended to 2438 m (8000 ft) Network Extended to 2438 m (8000 ft)24V dc(U

Strany 26 - Link Coupler

Publication 1761-UM004B-EN-P - June 200628 Network ConnectionsDF1 Master-slave Network with Modem DF1 Master-slave Network with ModemUse this d

Strany 27 - DH-485 Network

Publication 1761-UM004B-EN-P - June 2006Network Connections 29Avoid Incorrect Connections Incorrect ConnectionsIMPORTANTIn this configuration,

Strany 28 - Typical Three-node Network

Publication 1761-UM004B-EN-P - June 200630 Network Connections

Strany 29 - 1747-CP3 or

31 Publication 1761-UM004B-EN-P - June 2006Chapter 4Interpret the LED IndicatorsDiagnostics LED Indicators and Selector SwitchLED Indicator StatusLED

Strany 30 - 1761-CBL-HM02 Cable

Publication 1761-UM004B-EN-P - June 200632 Interpret the LED Indicators

Strany 31 - 1761-CBL-AM00 or

33 Publication 1761-UM004B-EN-P - June 2006Appendix ASpecifications and DimensionsGeneral SpecificationsAIC+ Advanced Interface Converter - 1761-NET-A

Strany 32 - 28 Network Connections

Publication 1761-UM004B-EN-P - June 200634 Specifications and DimensionsIsolation Between All Ports and Power Supply TerminalsHardware Handshak

Strany 33 - 1761-CBL-AS09 or

Publication 1761-UM004B-EN-P - June 2006Specifications and Dimensions 35Auto Transmit Delay (turnaround time) per Communication Rate Auto-trans

Strany 34 - 30 Network Connections

Publication 1761-UM004B-EN-P - June 20064 Summary of Changes

Strany 35 - Interpret the LED Indicators

Publication 1761-UM004B-EN-P - June 200636 Specifications and DimensionsMounting Template 52.07 mm (2.05 in.)118 mm (4.64 in.)107 mm (4.20 in.)

Strany 36

Publication 1761-UM004B-EN-P - June 2006IndexAAIC+ Advanced Interface Convertercompatibility with other devices 6connect to a network 21dimensions 36L

Strany 37 - Specifications and Dimensions

Publication 1761-UM004B-EN-P - June 20062 Index

Strany 38 - (turnaround time) is zero

Publication CIG-CO521C-EN-P- May 2003 PNXXXXXX-XX957782-91How Are We Doing?Your comments on our technical publications will help us serve you better

Strany 39

Other CommentsPLEASE FOLD HERENO POSTAGE NECESSARY IF MAILED IN THE UNITED STATESBUSINESS REPLY MAILFIRST-CLASS MAIL PERMIT NO. 18235 CLEVELAND OHPOST

Strany 41

Publication 1761-UM004B-EN-P - June 2006 7Supersedes Publication 1761-6.4 - April 1998 Copyright © 2006 Rockwell Automation, Inc. All rights reserved.

Strany 42 - 2 Index

i Publication 1761-UM004B-EN-P - June 2006Table of ContentsPrefaceWho Should Use This Manual . . . . . . . . . . . . . . . . . . . . . . . . 3Purpose

Strany 43 - How Are We Doing?

Publication 1761-UM004B-EN-P - June 2006ii Table of ContentsAppendix ASpecifications and DimensionsGeneral Specifications . . . . . . . . . . .

Strany 44 - BUSINESS REPLY MAIL

3 Publication 1761-UM004B-EN-P - June 2006PrefaceRead this preface to familiarize yourself with the rest of the manual. This preface covers the follow

Strany 45

Publication 1761-UM004B-EN-P - June 20064 PrefaceAdditional ResourcesThe following documents contain additional information regarding Rockwell

Strany 46 - Rockwell Automation

5 Publication 1761-UM004B-EN-P - June 2006Chapter 1Product OverviewDescriptionThe AIC+ advanced interface converter provides a communication link betw

Komentáře k této Příručce

Žádné komentáře