Publication 1760-UM003A-EN-P - September 2005
6-28 Application Examples for Pico
Example:
Data 1 (Byte 4) = 0xAC
Table 6.53 Operand overview
Index
(hex)
Operand Read Write
00 Parameters Table 6.54 x
01 Control byte Table 6.55 x
02 Actual value 1 T x
c
(2)
(2) The value can only be written if it is assigned to a constant in the program.
03 Time setpoint 1
S1
(1)
(1) A 16-bit value is transferred in data bytes Data 1 – Data 2. It should be remembered that Data 1 is the low byte
and Data 2 the high byte.
x
c
(2)
04 Time setpoint 2
S2
(1)
x
c
(2)
Table 6.54 Index 00 – Parameters
Meaning Bit7 6 543210
Appears in the parameter menu
Yes/no 0/1
Timer mode
On-delayed, 0 0 0
off-delayed. 0 0 1
On-delayed with random setpoint 0 1 0
Off-delayed with random setpoint 0 1 1
On and off delayed
(two time setpoints)
1 0 0
On and off delayed each with random
setpoint (two time setpoints)
1 0 1
Impulse transmitter 1 1 0
Flashing relay (two time setpoints) 1 1 1
Timebase
FB not used 0 0
Millisecond: S 0 1
Second: M:S 1 0
Minute: H:M 1 1
Use as constant and therefore can be written to
Time setpoint S1 0/1
Time setpoint S2 0/1