Publication 1756-IN019C-EN-P - November 2004
Installation Instructions
ControlLogix EtherNet/IP Bridge Module
Catalog Number 1756-ENBT
Use this document as a guide to install the module. Note that this document
describes hardware installation only. For configuration information, refer to
the EtherNet/IP Modules User Manual, publication number ENET-UM001,
available online at www.rockwellautomation.com/literature.
The following table lists the contents of this document and where to find
specific information.
Topic See Page
Important User InformationI 2
Identify Module Components 7
Prepare the Chassis for Module Installation 8
Determine Module Slot Location 9
Install the Module in the Chassis 10
Remove or Replace the Module (when applicable) 11
Install or Remove the Module Under Power 12
Wire the Ethernet Connector 13
Connect the Module to the EtherNet/IP Network 13
Apply Chassis Power 15
Check Power Supply and Module Status 15
Troubleshoot the Module 16
Where to Find Information on Configuring the Module 17
Specifications 18
Zobrazit stránku 0
1 2 3 4 5 6 ... 19 20

Shrnutí obsahu

Strany 1 - Installation Instructions

Publication 1756-IN019C-EN-P - November 2004Installation InstructionsControlLogix EtherNet/IP Bridge ModuleCatalog Number 1756-ENBTUse this document a

Strany 2

10 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Install the Module in the Chassis31275-M31276-MAlign the circ

Strany 3 - Environment and Enclosure

ControlLogix EtherNet/IP Bridge Module 11Publication 1756-IN019C-EN-P - November 2004Remove or Replace the Module (when applicable)IMPORTANTIf you

Strany 4

12 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Install or Remove the Module Under PowerThis module is design

Strany 5

ControlLogix EtherNet/IP Bridge Module 13Publication 1756-IN019C-EN-P - November 2004Wire the Ethernet ConnectorUse an RJ45 connector to connect t

Strany 6

14 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Attach the RJ45 connector to the Ethernet port on the bottom

Strany 7 - Identify Module Components

ControlLogix EtherNet/IP Bridge Module 15Publication 1756-IN019C-EN-P - November 2004Apply Chassis PowerCheck Power Supply and Module StatusCheck

Strany 8 - 1756-A4

16 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Troubleshoot the ModuleIf the alphanumeric display and LED in

Strany 9

ControlLogix EtherNet/IP Bridge Module 17Publication 1756-IN019C-EN-P - November 2004Link Status IndicatorThe Link Status LED provides the followi

Strany 10 - Publication

18 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004SpecificationsModule Location Any slot in the ControlLogix ch

Strany 11 - Slide module out of chassis

ControlLogix EtherNet/IP Bridge Module 19Publication 1756-IN019C-EN-P - November 2004Shock, Non-operatingIEC60068-2-27 (Test Ea, Unpackaged shock)

Strany 12

2 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004IImportant User InformationSolid state equipment has operation

Strany 13 - Wire the Ethernet Connector

Publication 1756-IN019C-EN-P - November 2004 PN 957944-26Supersedes Publication 1756-IN019B-EN-P - August 2001 Copyright © 2004 Rockwell Automation, I

Strany 14 - IMPORTANT

ControlLogix EtherNet/IP Bridge Module 3Publication 1756-IN019C-EN-P - November 2004Environment and Enclosure Prevent Electrostatic DischargeATTEN

Strany 15 - Apply Chassis Power

4 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Removal and Insertion Under PowerBe sure that power is removed

Strany 16 - Troubleshoot the Module

ControlLogix EtherNet/IP Bridge Module 5Publication 1756-IN019C-EN-P - November 2004North American Hazardous Location ApprovalThe following inform

Strany 17 - OK Status Indicator

6 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004WARNINGEXPLOSION HAZARD• Do not disconnect equipment unless po

Strany 18 - Specifications

ControlLogix EtherNet/IP Bridge Module 7Publication 1756-IN019C-EN-P - November 2004Identify Module ComponentsUse the following figure to identify

Strany 19

8 ControlLogix EtherNet/IP Bridge Module Publication 1756-IN019C-EN-P - November 2004Prepare the Chassis for Module InstallationBefore you install

Strany 20

ControlLogix EtherNet/IP Bridge Module 9Publication 1756-IN019C-EN-P - November 2004Determine Module Slot LocationYou can install the module in an

Komentáře k této Příručce

Žádné komentáře