Installation InstructionsArmorPoint I/O Modules with 8 Configurable 24V DC PointsCatalog Number(s) 1738-8CFGM8, 1738-8CFGM12, 1738-8CFGM23Topic PageIm
10 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010In RSLogix5000, the default tag will be Ada
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 11Publication 1738-IN026B-EN-E - February 2010• AdapterName:SlotNumber:C.PtPointNumberFau
12 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Interpret the Status Indicators 1738-8CFG
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 13Publication 1738-IN026B-EN-E - February 2010Network status Off Device is not online: -
14 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Specifications ArmorPoint Digital Modu
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 15Publication 1738-IN026B-EN-E - February 2010General SpecificationsAttribute ValueDimens
16 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010 Environmental SpecificationsAttribute Valu
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 17Publication 1738-IN026B-EN-E - February 2010CertificationsCertification (when product i
18 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Notes:
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 19Publication 1738-IN026B-EN-E - February 2010Notes:
2 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Important User InformationSolid state equipm
Publication 1738-IN026B-EN-E - February 2010Supersedes Publication 1738-IN026A-EN-E - August 2009 Copyright © 2010 Rockwell Automation, Inc. All right
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 3Publication 1738-IN026B-EN-E - February 2010Environment and EnclosurePrevent Electrostat
4 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010About the ModuleThe ArmorPoint I/O family co
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 5Publication 1738-IN026B-EN-E - February 2010Mount the I/O BaseMount the I/O base on a wa
6 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Install the mounting as follows:1. Lay out t
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 7Publication 1738-IN026B-EN-E - February 20102. Position the module vertically above the
8 ArmorPoint I/O Modules with 8 Configurable 24V DC Points Publication 1738-IN026B-EN-E - February 2010Wire the Module1738-8CFGM8 1738-8CFGM12ATTEN
ArmorPoint I/O Modules with 8 Configurable 24V DC Points 9Publication 1738-IN026B-EN-E - February 20101738-8CFGM23Communicate with Your ModuleRead
Komentáře k této Příručce