POINT I/O is a trademark of Rockwell Automation
DeviceNet is a trademark of ODVA, Inc. Publication 1734-IN586A-EN-P - December 2001
Installation Instructions
POINT I/O Protected Output Module
(Cat. No. 1734-OB2EP)
Description Description
1
Mounting Base
1
6 RTB Removal Handle
2 Mechanical Keying (orange) 7
Removable Terminal Block (RTB)
1
3 Module Wiring Diagram 8 DIN Rail Locking Screw (orange)
4 Module Locking Mechanism 9 Slide-in Writable Label
5 Insertable I/O Module 10 Interlocking Side Pieces
1
Wiring Base Assembly consists of item 1) mounting base, 1734-MB and item 7) removable
terminal block, 1734-RT or -RTS.
24V DC
Protected
Output
Module
Status
Network
Status
NODE:
0
1
1734
OB2EP
2
3
4
5
1
7
6
8
9
10
41825OB2E
Zobrazit stránku 0
1 2 3 4 5 6 ... 15 16

Shrnutí obsahu

Strany 1 - Installation Instructions

POINT I/O is a trademark of Rockwell AutomationDeviceNet is a trademark of ODVA, Inc. Publication 1734-IN586A-EN-P - December 2001Installation Instru

Strany 2 - Important User Information

10 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001dc Protected Output Module Cat. No. 1734-OB2EPOutput Terminal

Strany 3 - ATTENTION

POINT I/O Protected Output Module 11Publication 1734-IN586A-EN-P - December 2001Troubleshooting with the IndicatorsIndication Probable CauseMod

Strany 4 - Installing the I/O Module

12 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Indication Probable CauseNetwork StatusOff Device is not on-li

Strany 5

POINT I/O Protected Output Module 13Publication 1734-IN586A-EN-P - December 2001Safety ApprovalsThe following information applies when operatin

Strany 6 - Removing a Mounting Base

14 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Specifications - 1734-OB2EP Protected Output ModuleOutput Spec

Strany 7

POINT I/O Protected Output Module 15Publication 1734-IN586A-EN-P - December 2001Environmental ConditionsOperational Temperature IEC 60068-2-1 (

Strany 8

Publication 1734-IN586A-EN-P - December 2001 PN 957536-73© 2001 Rockwell International Corporation. Printed in USAAgency Certification (when product i

Strany 9 - V = Supply

2 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Important User InformationBecause of the variety of uses for th

Strany 10 - 1734-OB2EP

POINT I/O Protected Output Module 3Publication 1734-IN586A-EN-P - December 2001IMPORTANTIdentifies information that is critical for successful

Strany 11

4 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Installing the Mounting BaseTo install the mounting base on the

Strany 12

POINT I/O Protected Output Module 5Publication 1734-IN586A-EN-P - December 2001module into the mounting base. In addition, make sure the mounti

Strany 13 - AVERTISSEMENT

6 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Installing the Removable Terminal Block (RTB)A removable termin

Strany 14

POINT I/O Protected Output Module 7Publication 1734-IN586A-EN-P - December 20013. Press on the module lock on the top of the module.4. Pull on

Strany 15

8 POINT I/O Protected Output Module Publication 1734-IN586A-EN-P - December 2001Communicating with Your ModuleI/O messages are sent to (consume

Strany 16

POINT I/O Protected Output Module 9Publication 1734-IN586A-EN-P - December 2001Wiring the Protected Output ModulesProtectedSourcingOutputModule