1 Publication 1405-IN001B-EN-P - October 2003
Installation Instructions
Bulletin 1405 (M610) Operating Instructions
Overview
The MiniPowermonitor (1405-M610) measures and displays voltage
and current parameters of low voltage AC power systems:
Line-to-neutral and line-to-line voltages
Instantaneous currents
15-minute averaged currents
Peak currents
The MiniPowermonitor is a compact unit, with a 96 x 96 mm (3.78 x
3.78 in) front panel and a depth of only 65 mm (2.56 in).
The module’s display is arranged in 3 lines, each with 4 digits. The red
14 mm (0.55 in) high LED characters are easily readable from a
distance, in high ambient light conditions, and from acute viewing
angles. The measurement mode is indicated by 5 LED lamps that
show which parameter is displayed at that time.
Phase voltage and current measurements are made by sequential
scanning at 2 samples per second, so that 3 phase measurements are
made in 1.5 seconds. The updated average current value is displayed
approximately every 60 seconds, interjected into the cyclical sequence
of displayed parameters. Parameter values can be read out of
sequence, using the function (F) key on the front panel.
L-L
L-N
15min
max
V
V
F
A
L1
L1-L2
L2
L2-L3
L3
L1-L3
Zobrazit stránku 0
1 2 3 4 5 6 ... 11 12

Shrnutí obsahu

Strany 1 - Overview

1 Publication 1405-IN001B-EN-P - October 2003Installation InstructionsBulletin 1405 (M610) Operating InstructionsOverviewThe MiniPowermonitor (1405-M6

Strany 2 - Installation

Publication 1405-IN001B-EN-P - October 200310 Bulletin 1405 (M610) Operating Instructions

Strany 3 - Input Connections

Publication 1405-IN001B-EN-P - October 2003Bulletin 1405 (M610) Operating Instructions 11

Strany 4 - The actual value is 2.5A

Publication 1405-IN001B-EN-P - October 2003 12 PN 40055-219-01(2)Supersedes Publication 1405-IN001A-EN-P - July 2003 Copyright © 2003 Rockwell Automat

Strany 5 - Measuring Operation

Publication 1405-IN001B-EN-P - October 20032 Bulletin 1405 (M610) Operating InstructionsInstallationOnly qualified personnel should install and wi

Strany 6

Publication 1405-IN001B-EN-P - October 2003Bulletin 1405 (M610) Operating Instructions 3Input ConnectionsInput connections are at the rear, throug

Strany 7

Publication 1405-IN001B-EN-P - October 20034 Bulletin 1405 (M610) Operating InstructionsCurrent Transformer Ratio Setting and Display Test To sele

Strany 8 - Product Approvals

Publication 1405-IN001B-EN-P - October 2003Bulletin 1405 (M610) Operating Instructions 5When the desired value is reached, the module is switched

Strany 9

Publication 1405-IN001B-EN-P - October 20036 Bulletin 1405 (M610) Operating InstructionsDimensionsPanel cut-outs should be 92 x 92 mm (3.6 x 3.6 i

Strany 10

Publication 1405-IN001B-EN-P - October 2003Bulletin 1405 (M610) Operating Instructions 7Temperature Coefficient < 0.01% / KInput Impedance (Vol

Strany 11

Publication 1405-IN001B-EN-P - October 20038 Bulletin 1405 (M610) Operating InstructionsProduct ApprovalsUL/CULcULus Listed, File E96956, per UL50

Strany 12 - Installation Assistance

Publication 1405-IN001B-EN-P - October 2003Bulletin 1405 (M610) Operating Instructions 9Catalog Number ExplanationBulletin Number1405-M610-400-1AD

Komentáře k této Příručce

Žádné komentáře