1–7Getting Started
1336 FORCE — 5.9 August 1995
Step 3 — Enter a Multiplexer Block
To add a Multiplexer function block:
1. Move the cursor to the left side of the execution list and click.
2. Select the A
dd Block option from the Function Blocks
pull-down menu.
3. Double click on Multiplexer — [Lib ID: 21].
4. Click on CLOSE.
As shown below, the DriveBlockEditor software now enters a
Multiplexer function block and gives it an ID # of 3.
5. Enter a value for input 1 by clicking on the Value field for Node
0 and entering +32767.
Press enter to save the value as shown below.
6. Enter a value for input 2 by clicking on the Value field for Node
1 and entering –32767.
Press enter to save the value as shown above.