Publication 1394-5.0 May 2000
9-4 Troubleshooting
For this module: For this LED:
Status of the
LED:
Potential Cause: Possible resolution:
Axis Module Status
Steady red Malfunctioning axis module.
Verify wiring.
Verify that the slider and terminator are
securely engaged.
Secure wiring connections.
Replace the module.
Flashing red Axis fault has occurred.
Verify wiring.
Secure wiring connections.
Check fault status on the HIM (Analog
Servo only), in GML (GMC only), or on the
operator panel (CNC Interface and 9/440).
Check 460V AC input power.
Check axis status on the HIM (Analog
Servo only), in GML (GMC only), and on
the operator panel (CNC Interface and
9/440)
Alternating
red and
green
DC bus is not up.
Check the system modules LED.
Check slider connections to verify that they
are properly seated.
Verify that the terminator is present on the
last axis.
Flashing
green
Axis is not enabled.
Check axes and enable them, if necessary.
Verify that enable wiring is correct and not
open.
Enable signal from position
controller is not present (Analog
Servo only).
Check axes and enable them, if necessary.
Verify that enable wiring is correct and not
open.
Incorrect wiring or loose
connections.
Check connections on the input wiring board.
Axis setups may not be correct for
the application.
Verify that axis definitions are correct.
Check tuning parameters.
Not
illuminated
There is no power to the axis
module.
Verify that the terminator is present on the last
axis.
There is no power to the system.
Verify that the terminator is present on the
last axis.
Check system module power supply.