Product Overview
Appendix
A
A –11
Environmental Conditions
Condition Range
Operating temperature
0° C to 60° C (32° F to 140° F)
Storage temperature
–40° C to 85° C (–40° F to 185° F)
Relative humidity 5% to 95% (non–condensing)
Backplane Power Consumption
Operating voltage Current requirement
5V dc
.75 Amps
Important: The BASIC module receives its power from the 1771-I/O
backplane. The power consumption of the BASIC module must be taken
into consideration when planning your PLC system. Refer to the
documentation supplied with your PLC processor or 1771-I/O equipment
for additional information on power supplies and current requirements.
Port Driver and Receiver
Drive output Receiver sensitivity
+3.6 V minimum
200 mV minimum
Module Location
One 1771 I/O chassis module slot. See Chapter 1 for further details.
Keying
Top backplane connector:
between 8 and 10
between 32 and 34
See Chapter 1 for further details.