Rockwell-automation 1762-IR4 RTD/Resistance Input Module Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Zařízení Rockwell-automation 1762-IR4 RTD/Resistance Input Module. Rockwell Automation 1762-IR4 RTD/Resistance Input Module User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 104
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
MicroLogix™ 1200
RTD/Resistance
Input Module
(Catalog Number 1762-IR4)
User Manual
Zobrazit stránku 0
1 2 3 4 5 6 ... 103 104

Shrnutí obsahu

Strany 1 - Input Module

MicroLogix™ 1200 RTD/Resistance Input Module(Catalog Number 1762-IR4)User Manual

Strany 2 - Important User Information

Publication 1762-UM003A-EN-P - February 20034 Preface

Strany 3 - Table of Contents

Publication 1762-UM003A-EN-P - February 20034 IndexWwiring 2-1input devices 2-11routing considerations 2-4terminal block 2-10terminal screw tor

Strany 7 - How to Use This Manual

Publication 1762-UM003A-EN-P - February 2003 9Copyright © 2003 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Strany 8 - Conventions Used in This

1 Publication 1762-UM003A-EN-P - February 2003Chapter 1OverviewThis chapter describes the four-channel 1762-IR4 RTD/resistance Input module and explai

Strany 9 - Rockwell Automation

Publication 1762-UM003A-EN-P - February 20031-2 OverviewThe following data formats are supported by the module.:• raw/proportional• engineering

Strany 10 - 4 Preface

Publication 1762-UM003A-EN-P - February 2003Overview 1-3Table 1.1 RTD SpecificationsRTD Type(1)Temperature Range Using 0.5 mA ExcitationTempera

Strany 11 - Overview

Publication 1762-UM003A-EN-P - February 20031-4 OverviewThe tables below provide specifications for RTD accuracy and temperature drift.Table 1.

Strany 12 - RTD Compatibility

Publication 1762-UM003A-EN-P - February 2003Overview 1-5Resistance Device CompatibilityThe following table lists the specifications for the res

Strany 13 - Ω per DIN standard

Publication 1762-UM003A-EN-P - February 20031-6 OverviewHardware FeaturesThe RTD/resistance module provides connections for four 3-wire inputs

Strany 14 - 1-4 Overview

Publication 1762-UM003A-EN-P - February 2003Overview 1-7System OverviewThe modules communicate to the local controller or communication adapter

Strany 15 - Overview 1-5

Publication 1762-UM003A-EN-P - February 20031-8 OverviewModule OperationAs shown in the block diagram below, each input channel of the module c

Strany 16 - Hardware Features

1 Publication 1762-UM003A-EN-P - February 2003Chapter 2Installation and WiringThis chapter tells you how to:• determine the power requirements for the

Strany 17 - System Overview

Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use

Strany 18 - Module Field Calibration

Publication 1762-UM003A-EN-P - February 20032-2 Installation and WiringFor specific information required by EN61131-2, see the appropriate sect

Strany 19 - Installation and Wiring

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-3Hazardous Location ConsiderationsThis equipment is suitable for use in C

Strany 20 - General Considerations

Publication 1762-UM003A-EN-P - February 20032-4 Installation and WiringRemove PowerSelecting a LocationReducing NoiseMost applications require

Strany 21

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-5MountingMinimum SpacingMaintain spacing from enclosure walls, wireways,

Strany 22 - Selecting a Location

Publication 1762-UM003A-EN-P - February 20032-6 Installation and WiringDIN Rail MountingThe module can be mounted using the following DIN rails

Strany 23 - Mounting

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-7System AssemblyThe expansion I/O module is attached to the controller or

Strany 24 - Panel Mounting

Publication 1762-UM003A-EN-P - February 20032-8 Installation and WiringField Wiring ConnectionsSystem Wiring GuidelinesConsider the following w

Strany 25 - System Assembly

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-9• Keep shield connection to ground as short as possible.• If noise persi

Strany 26 - Field Wiring Connections

Publication 1762-UM003A-EN-P - February 20032-10 Installation and WiringWiring the Finger-Safe Terminal BlockWhen wiring the terminal block, ke

Strany 27 - RTD Wiring Considerations

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-11Wire Size and Terminal Screw TorqueEach terminal accepts up to two wire

Strany 28

1 Publication 1762-UM003A-EN-P - February 2003Table of ContentsPrefaceWho Should Use This Manual . . . . . . . . . . . . . . . . . . . . . . P-1How t

Strany 29

Publication 1762-UM003A-EN-P - February 20032-12 Installation and WiringTo wire your module follow these steps:1. At each end of the cable, str

Strany 30 - Wiring RTDs

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-132-Wire RTD Configuration3-Wire RTD ConfigurationIMPORTANTUsing 2-wire c

Strany 31 - 3-Wire RTD Configuration

Publication 1762-UM003A-EN-P - February 20032-14 Installation and Wiring4-Wire RTD ConfigurationWiring Resistance Devices (Potentiometers)Poten

Strany 32 - 4-Wire RTD Configuration

Publication 1762-UM003A-EN-P - February 2003Installation and Wiring 2-153-Wire Potentiometer InterconnectionIMPORTANTUsing 2-wire configuration

Strany 33

Publication 1762-UM003A-EN-P - February 20032-16 Installation and Wiring

Strany 34

1 Publication 1762-UM003A-EN-P - February 2003Chapter 3Module Data, Status, and Channel ConfigurationAfter installing the 1762-IR4 RTD/resistance inpu

Strany 35 - Configuration

Publication 1762-UM003A-EN-P - February 20033-2 Module Data, Status, and Channel ConfigurationInput ImageThe input image file represents data w

Strany 36 - Accessing Input Image File

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-3Input Data FileThe input data table allows you to

Strany 37 - Input Data Values

Publication 1762-UM003A-EN-P - February 20033-4 Module Data, Status, and Channel ConfigurationInput Data Not Valid ConditionThe general status

Strany 38

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-5Over-Range Flag Bits (O0 to O3)Over-range bits fo

Strany 39 - Configuring Channels

Publication 1762-UM003A-EN-P - February 20032 Table of ContentsChapter 3Module Data, Status, and Channel ConfigurationModule Memory Map . . . . . . .

Strany 40 - Configuration Data File

Publication 1762-UM003A-EN-P - February 20033-6 Module Data, Status, and Channel ConfigurationConfiguration Data FileThe configuration data fil

Strany 41 - Channel Configuration

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-7The following table shows the basic arrangement o

Strany 42 - Decimals

Publication 1762-UM003A-EN-P - February 20033-8 Module Data, Status, and Channel ConfigurationTable 3.4 Channel Configuration Bit DefinitionsTo

Strany 43

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-9Enabling or Disabling a Channel (Bit 15)Bit 15 en

Strany 44 - Raw/Proportional Data Format

Publication 1762-UM003A-EN-P - February 20033-10 Module Data, Status, and Channel ConfigurationRaw/Proportional Data FormatThe raw/proportional

Strany 45 - ±200 ˚C

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-11Figure 3.1 Linear Relationship Between Temperatu

Strany 46

Publication 1762-UM003A-EN-P - February 20033-12 Module Data, Status, and Channel ConfigurationEXAMPLEEngineering Units x1 to Scaled-for-PID• i

Strany 47 - Scaled-for-PID Data Format

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-13Engineering Units x 1 Data FormatIf you select e

Strany 48 - +850 ˚C -200 ˚C

Publication 1762-UM003A-EN-P - February 20033-14 Module Data, Status, and Channel ConfigurationLinear Relationship Between Temperature and PID

Strany 49

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-15Selecting Temperature Units/Mode (Bit 7)The modu

Strany 50

Publication 1762-UM003A-EN-P - February 2003Table of Contents 3Power-up Diagnostics . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

Strany 51 - Channel Step Response

Publication 1762-UM003A-EN-P - February 20033-16 Module Data, Status, and Channel ConfigurationSelecting Cyclic Lead Compensation (Bit 4)For ea

Strany 52 - Channel Cutoff Frequency

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-17The choice that you make for filter frequency wi

Strany 53 - Frequency Response Graphs

Publication 1762-UM003A-EN-P - February 20033-18 Module Data, Status, and Channel Configurationthe channel filter. The channel step response is

Strany 54 - Resolution and Range

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-19Frequency Response Graphs–3 dB36003001801206015

Strany 55

Publication 1762-UM003A-EN-P - February 20033-20 Module Data, Status, and Channel ConfigurationSelecting Enable/Disable Cyclic Autocalibration

Strany 56

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-21Table 3.9 Effective Resolution and Range for 10

Strany 57

Publication 1762-UM003A-EN-P - February 20033-22 Module Data, Status, and Channel ConfigurationTable 3.10 Effective Resolution and Range for 50

Strany 58

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-23Table 3.11 Effective Resolution and Range for 25

Strany 59

Publication 1762-UM003A-EN-P - February 20033-24 Module Data, Status, and Channel ConfigurationTable 3.12 Effective Resolution and Range for 50

Strany 60

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-25Table 3.13 Effective Resolution and Range for 1

Strany 61 - Update Time

Publication 1762-UM003A-EN-P - February 20034 Table of Contents

Strany 62

Publication 1762-UM003A-EN-P - February 20033-26 Module Data, Status, and Channel ConfigurationThe table below identifies the number of signifi

Strany 63

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-27Determining Module Update TimeThe module update

Strany 64

Publication 1762-UM003A-EN-P - February 20033-28 Module Data, Status, and Channel ConfigurationModule update time can be calculated by obtainin

Strany 65 - Compensation Enabled

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-29Calculating Module Update Time with Autocalibrat

Strany 66 - Module Startup

Publication 1762-UM003A-EN-P - February 20033-30 Module Data, Status, and Channel ConfigurationEffects of Cyclic Lead Wire Compensation on Modu

Strany 67 - Effects of Autocalibration

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-31Calculating Module Update Time with Cyclic Lead

Strany 68

Publication 1762-UM003A-EN-P - February 20033-32 Module Data, Status, and Channel ConfigurationImpact of Autocalibration and Lead Wire Compensa

Strany 69 - Safety Considerations

Publication 1762-UM003A-EN-P - February 2003Module Data, Status, and Channel Configuration 3-33Effects of Autocalibration on AccuracyThe module

Strany 70 - Channel Operation

Publication 1762-UM003A-EN-P - February 20033-34 Module Data, Status, and Channel Configuration

Strany 71 - Channel Diagnostics

1 Publication 1762-UM003A-EN-P - February 2003Chapter 4Diagnostics and TroubleshootingThis chapter describes module troubleshooting, containing inform

Strany 72 - Module Errors

1 Publication 1762-UM003A-EN-P - February 2003PrefaceRead this preface to familiarize yourself with the rest of the manual. This preface covers the fo

Strany 73 - Module Error Definition

Publication 1762-UM003A-EN-P - February 20034-2 Diagnostics and TroubleshootingActivating Devices When TroubleshootingWhen troubleshooting, nev

Strany 74 - Configuration Errors

Publication 1762-UM003A-EN-P - February 2003Diagnostics and Troubleshooting 4-3Internal diagnostics are performed at both levels of operation.

Strany 75 - Error Codes

Publication 1762-UM003A-EN-P - February 20034-4 Diagnostics and TroubleshootingPossible causes for an out-of-range condition include:• The temp

Strany 76 - Automation

Publication 1762-UM003A-EN-P - February 2003Diagnostics and Troubleshooting 4-5Module Error Definition TableModule errors are expressed in two

Strany 77 - Specifications

Publication 1762-UM003A-EN-P - February 20034-6 Diagnostics and TroubleshootingExtended Error Information FieldCheck the extended error informa

Strany 78 - Input Specifications

Publication 1762-UM003A-EN-P - February 2003Diagnostics and Troubleshooting 4-7Error CodesThe table below explains the extended error code.Tabl

Strany 79 - Specifications A-3

Publication 1762-UM003A-EN-P - February 20034-8 Diagnostics and TroubleshootingModule Inhibit FunctionWhenever the 1762-IR4 module is inhibited

Strany 80 - RTD Standards

1 Publication 1762-UM003A-EN-P - February 2003Appendix ASpecificationsGeneral SpecificationsSpecification ValueDimensions 90 mm (height) x 87 mm (dept

Strany 81 - Positive Decimal Values

Publication 1762-UM003A-EN-P - February 2003A-2 SpecificationsInput SpecificationsSpecification 1762-IR4Input Types • 100Ω Platinum 385 • 200Ω

Strany 82 - Negative Decimal Values

Publication 1762-UM003A-EN-P - February 2003Specifications A-3Specification 1762-IR4Accuracy Drift at 0 to 55° C (+32 to +131°F)±0.026°C/°C (0.

Strany 83 - I1:e.4/2

Publication 1762-UM003A-EN-P - February 20032 PrefaceRelated DocumentationThe table below provides a listing of publications that contain im

Strany 84 - RSLogix 500 Version 5.50 or

Publication 1762-UM003A-EN-P - February 2003A-4 SpecificationsCable SpecificationsRTD StandardsDescription Belden #9501 Belden #9533 Belden #83

Strany 85

1 Publication 1762-UM003A-EN-P - February 2003Appendix CTwo’s Complement Binary NumbersThe processor memory stores 16-bit binary numbers. Two’s comple

Strany 86

Publication 1762-UM003A-EN-P - February 2003C-2 Two’s Complement Binary NumbersNegative Decimal ValuesIn two’s complement notation, the far lef

Strany 87

1 Publication 1762-UM003A-EN-P - February 2003Appendix BConfiguring the 1762-IR4 Module Using RSLogix 500This appendix examines the 1762-IR4 module’s

Strany 88 - RSLogix 500 Version 5.2 or

Publication 1762-UM003A-EN-P - February 2003B-2 Configuring the 1762-IR4 Module Using RSLogix 500The default configuration is as follows:Config

Strany 89

Publication 1762-UM003A-EN-P - February 2003Configuring the 1762-IR4 Module Using RSLogix 500 B-3While offline, double-click on the IO Configur

Strany 90

Publication 1762-UM003A-EN-P - February 2003B-4 Configuring the 1762-IR4 Module Using RSLogix 500The 1762-IR4 module is installed in slot 1. To

Strany 91 - Glossary

Publication 1762-UM003A-EN-P - February 2003Configuring the 1762-IR4 Module Using RSLogix 500 B-5Use the Calibration tab (Cal) to disable cycli

Strany 92 - 2 Glossary

Publication 1762-UM003A-EN-P - February 2003B-6 Configuring the 1762-IR4 Module Using RSLogix 500Configuration Using RSLogix 500 Version 5.2 or

Strany 93 - Glossary 3

Publication 1762-UM003A-EN-P - February 2003Configuring the 1762-IR4 Module Using RSLogix 500 B-7Enter -15597 into the Generic Extra Data Confi

Strany 94 - Function

Publication 1762-UM003A-EN-P - February 2003Preface 3Rockwell Automation SupportRockwell Automation tests all of our products to ensure that th

Strany 95 - Glossary 5

Publication 1762-UM003A-EN-P - February 2003B-8 Configuring the 1762-IR4 Module Using RSLogix 500

Strany 96 - 6 Glossary

1 Publication 1762-UM003A-EN-P - February 2003GlossaryThe following terms and abbreviations are used throughout this manual. For definitions of terms

Strany 97

Publication 1762-UM003A-EN-P - February 20032 Glossarycommon mode voltage rangeThe largest voltage difference allowed between either the pos

Strany 98 - 2 Index

Publication 1762-UM003A-EN-P - February 2003Glossary 3filterA device that passes a signal or range of signals and eliminates all others.filter

Strany 99 - Index 3

Publication 1762-UM003A-EN-P - February 20034 Glossaryfull-scale input. See the variation from the straight line due to linearity error (exa

Strany 100 - 4 Index

Publication 1762-UM003A-EN-P - February 2003Glossary 5overall accuracyThe worst-case deviation of the digital representation of the input signa

Strany 101

Publication 1762-UM003A-EN-P - February 20036 Glossary

Strany 102

Publication 1762-UM003A-EN-P - February 2003IndexAA/Ddefinition G-1A/D converter 1-8, 3-9abbreviations G-1accuracyautocalibration 3-33module 3-33overa

Strany 103

Publication 1762-UM003A-EN-P - February 20032 IndexEeffective resolution1 kHz 3-2510 Hz 3-21250 Hz 3-23500 Hz 3-2450-60 Hz 3-22definition G-2nu

Strany 104

Publication 1762-UM003A-EN-P - February 2003Index 3multiplexerdefinition G-4multiplexing 1-8Nnegative decimal values C-2noise 3-17noise rejecti

Komentáře k této Příručce

Žádné komentáře